We map your sites and assets to build your service program.

Nobody likes warm soda.
Planned HVAC and refrigeration programs that protect uptime and customer expectations for convenience store chains and fuel networks, self-performed at every location.

A convenience store runs one rooftop unit, no spare, and for extended operating hours if not 24/7. The store footprint usually has a prepared foods area. The cold vault never stops. And fuel island dust and grease-laden return air load coils and filters faster here than in a conditioned retail box.
That load is not small. EPA’s ENERGY STAR benchmarks put a convenience store at 883.5 thousand Btu of source energy per square foot against 120.0 for a retail store — roughly seven times the energy in the same amount of building. EPA also puts refrigeration alone at up to 40% of a c-store’s total.
And when a unit finally gives up, the decision gets made under duress. CalMTA’s 2025 market study puts unplanned replacements at about 80% of rooftop unit purchases — bought after the failure, at whatever is on the truck that day, and that choice sets the store’s efficiency for the next sixteen years. Coil cleaning and filter changes on a schedule are what keep that decision from arriving early.
What gets done and what moves the interval in a small footprint that never slows down. The cadence is set per site and each planned and scheduled visit is documented.
| Service | What determines the cadence |
|---|---|
| Refrigerated case and cooler cleaning Glass-door cold vault, reach-in cases and back-room walk-ins |
Door-cycle counts on a glass-door cold vault, and foodservice humidity carried into the same room. |
| Condenser and evaporator coil cleaning Condensers and evaporators on the rooftop unit and on refrigeration |
Fuel island dust, coastal salt, cottonwood, and a unit that runs close to capacity most of the day. |
| HVAC filter changes Rooftop units serving the sales floor and the foodservice area |
Grease-laden return air from fryers and roller grills loads filters faster than any published interval assumes. |
| Return air vent cleaning Return vents and grilles across a single enclosed sales floor |
A small enclosed sales floor with foodservice in it, where airflow and odor are the same problem. |
| Fan belt replacement Rooftop units and restroom or kitchen exhaust fans |
No redundancy. There is no second unit to carry the store while a belt is replaced. |
Our structured approach takes customers from onboarding to consistent execution, clear visibility, and measurable success across every site.

We map your sites and assets to build your service program.

We align on services, frequency, and your work order and invoicing processes.

We build a route-optimized schedule for each location.

Service can begin within 45 days of signing.

Every visit is verified and documented in your customer portal.

We review quality, SLAs, and KPIs on your preferred cadence.

Our technicians photograph and log what they find on each service visit at every store location. Not just the before and after of each service they perform, but other things they see while there. Loose roof top mats. A broken condensate drain line. Wasps nesting in an RTU.
Those site issues go into ReportLink™ with photos, notes, and location detail, so a territory manager or the corporate facilities team can review and take the appropriate actions. Our technicians identify 40k+ site issues every year, and every one of them reaches our customers unpriced.
BFC does planned work only and never quotes a repair, so the report in your hands was not written by anyone who stood to gain from what it says.
Essential services that keep HVAC units performing as intended. Planned, scheduled, and 100% self-performed.
Dust off the fuel island builds up on the condenser coil and acts like insulation. Airflow drops, and the compressor works harder for the same cooling. Pacific Northwest National Laboratory measured it: cut the airflow through a condenser coil in half and the unit gives up 9% of its capacity and 22% of its efficiency. That arrives as electricity on your already high energy bill. Here is what a coil looks like before and after a planned cleaning.



Standard box filters are designed half an inch short on each side, and unfiltered air takes the gap around and in-between them on a filter track. That is not a maintenance issue — it is a design flaw, and no filter schedule fixes it. On a c-store rooftop, with the fuel island right there and the door cycling hundreds of times a day, it means dust and debris the filter never sees. Tiger striping on an evaporator coil is those gaps made visible — the effects of which multiple across all your locations.
The PleatLink® Filtration System was patented in 2000 to close the gaps, and is manufactured at our facility in Nashville. The media extends an inch beyond the frame top and bottom, forming a gasket-like seal that fills the whole filter track. MERV 8 and MERV 13, tested to ASHRAE standards by Blue Heaven Technologies, and specification-matched per unit. Continuous media, reusable metal frame, and cardboard-free.
The routine HVAC work is the same at every site. Same filters, coils, and belts, same intervals. Your work goes beyond the program itself to the problems that land on your desk. We can help.

Staffing shortages leave in-house teams stretched thin, and planned work is the first thing to skip or defer when something breaks. We self-perform on a set schedule and hold the service intervals, so store staff stay focused on customers.

A brand standard is hard to hold when each location uses a different HVAC vendor. One provider, one consistent scope and execution standards, with all locations on the same cadence.

You answer for every site, on work you don’t perform yourself, so you need proof rather than assurance the work took place. Every visit is documented in ReportLink™ — dated and photographed, with visibility to all locations in your network.
Planned and scheduled service programs, adapted to each industry’s wear on HVAC systems.